| Modelo | SUN-3K-SG05 LP3-EU-SM2 | SUN-4K-SG05 LP3-EU-SM2 | SUN-5K-SG05 LP3-EU-SM2 | SUN-6K-SG05 LP3-EU-SM2 | SUN-8K-SG05 LP3-EU-SM2 | SUN-10K-SG05 LP3-EU-SM2 | SUN-12K-SG05 LP3-EU-SM2 | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Battery Input Data | – | – | – | – | – | – | – | ||||
| Battery Type | Lead-acid or Lithium-ion | – | – | – | – | – | – | ||||
| Battery Voltage Range(V) | 40-60 | – | – | – | – | – | – | ||||
| Max.Charging Current(A) | 70 | 95 | 120 | 135 | 190 | 210 | 240 | ||||
| Max.Discharging Current(A) | 70 | 95 | 120 | 135 | 190 | 210 | 240 | ||||
| Charging Strategy for Li-ion Battery | Self-adaption to BMS | – | – | – | – | – | – | ||||
| Number of battery input | 1 | – | – | – | – | – | – | ||||
| PV String Input Data | – | – | – | – | – | – | – | ||||
| Max. PV Access Power (W) | 6000 | 8000 | 10000 | 12000 | 16000 | 20000 | 24000 | ||||
| Max PV Input Power(W) | 4500 | 6400 | 8000 | 9600 | 12800 | 16000 | 19200 | ||||
| Max PV Input Voltage(V) | 800 | – | – | – | – | – | – | ||||
| Start-up Voltage(V) | 160 | – | – | – | – | – | – | ||||
| MPPT Voltage Range(V) | 200-650 | – | – | – | – | – | – | ||||
| Rated PV Input Voltage(V) | 550 | – | – | – | – | – | – | ||||
| Max Input Short-Circuit Current(A) | 30+30 | 39+39 | – | – | – | – | – | ||||
| Max Operating PV Input Current(A) | 20+20 | 26+26 | – | – | – | – | – | ||||
| No.of MPP Trackers/No.of String Per MPP Tracker | 2/1+1 | 2/2+2 | – | – | – | – | – | ||||
| AC Input /Output Data | – | – | – | – | – | – | – | ||||
| Rated AC Input/Output Active Power(W) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | ||||
| Max AC Input/Output Apparent Power (VA) | 3300 | 4400 | 5500 | 6600 | 8800 | 11000 | 13200 | ||||
| Rated AC Input/Output Current(A) | 4.6/4.4 | 6.1/5.8 | 7.6/7.3 | 9.1/8.7 | 12.2/11.6 | 15.2/14.5 | 18.2/17.4 | ||||
| Max AC Input/Output Current(A) | 5/4.8 | 6.7/6.4 | 8.4/8 | 10/9.6 | 13.4/12.8 | 16.7/16 | 20/19.2 | ||||
| Max Continuous AC Passthrough (grid to load)(A) | 45 | – | – | – | – | – | – | ||||
| Peak Power (off-grid)(W) | 2 times of rated power,10s | – | – | – | – | – | – | ||||
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | – | – | – | – | – | – | ||||
| Rated Input/Output Voltage/Range(V) | 220/380V, 230/400V 0.85Un-1.1Un | – | – | – | – | – | – | ||||
| Grid Connection Form | 3L+N+PE | – | – | – | – | – | – | ||||
| Rated Input/Output Grid Frequency/Range | 50/45-55, 60/55-65 | – | – | – | – | – | – | ||||
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | – | – | – | – | – | – | ||||
| DC Injection Current | <0.5% In | – | – | – | – | – | – | ||||
| Efficiency | – | – | – | – | – | – | – | ||||
| Max Efficiency | 97.6% | – | – | – | – | – | – | ||||
| Euro Efficiency | 97.0% | – | – | – | – | – | – | ||||
| MPPT Efficiency | >99% | – | – | – | – | – | – | ||||
| Equipment Protection | – | – | – | – | – | – | – | ||||
| Integrated | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | – | – | – | – | – | – | ||||
| Surge Protection Level | TYPE II(DC),TYPE II(AC) | – | – | – | – | – | – | ||||
| Interface | – | – | – | – | – | – | – | ||||
| Communication Interface | RS485/RS232/CAN | – | – | – | – | – | – | ||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) | – | – | – | – | – | – | ||||
| General Data | – | – | – | – | – | – | – | ||||
| Operating Temperature Range | -40 to+60℃,>45℃ Derating | – | – | – | – | – | – | ||||
| Permissible Ambient Humidity | 0~100% | – | – | – | – | – | – | ||||
| Permissible Altitude | 3000m | – | – | – | – | – | – | ||||
| Noise (dB) | ≤55 | – | – | – | – | – | – | ||||
| Ingress Protection(IP) Rating | IP 65 | – | – | – | – | – | – | ||||
| Inverter Topology | Non-Isolated | – | – | – | – | – | – | ||||
| Over Voltage Category | OVC II(DC),OVC III(AC) | – | – | – | – | – | – | ||||
| Cabinet Size (WxHxD mm) | 386×660×250 (Excluding Connectors and Brackets) | – | – | – | – | – | – | ||||
| Weight[kg] | 35.2 | – | – | – | – | – | – | ||||
| Warranty | 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | – | – | – | – | – | – | ||||
| Type Of Cooling | Intelligent Air Cooling | – | – | – | – | – | – | ||||
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99,VDE-AR-N 4105 | – | – | – | – | – | – | ||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | – | – | – | – | – | – | ||||