Product


| Model | SUN-3K-G06P3-EU-BM2 | SUN-4K-G06P3-EU-BM2 | SUN-5K-G06P3-EU-BM2 | SUN-6K-G06P3-EU-BM2 | SUN-7K-G06P3-EU-BM2 | SUN-8K-G06P3-EU-BM2 | SUN-9K-G06P3-EU-BM2 | SUN-10K-G06P3-EU-BM2 | SUN-SUN-12K-G06P3-EU-BM23.6K-G05P1-EU-AM1 | SUN-15K-G06P3-EU-BM2 | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PV String Input Date | ||||||||||||||
| Max. PV Input Power(kW) | 4.5 | 6 | 7.5 | 9 | 10.5 | 12 | 13.5 | 15 | 18 | 22.5 | ||||
| Max. PV Input Voltage(V) | 1100 | |||||||||||||
| Start-up Voltage(V) | 140 | |||||||||||||
| MPPT voltage range(V) | 120-1000 | |||||||||||||
| Rated PV Input voltage(V) | 600 | |||||||||||||
| Max. Operating PV Input Current (A) | 13+13 | 13+26 | ||||||||||||
| Max. Input Short Circuit Current (A) | 19.5+19.5 | 19.5+39 | ||||||||||||
| No. of MPP Trackers/No. of Strings MPP Tracker | 2/1+1 | 2/1+2 | ||||||||||||
| AC Output Side | 1 | 1.5 | 2 | 2.2 | 2.5 | 2.7 | 3 | 3.3 | 3.6 | 4 | ||||
| Rated AC Output Active Power (kW) | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 12 | 15 | ||||
| Max. AC Output Apparent Power (kVA) | 3.3 | 4.4 | 5.5 | 6.6 | 7.7 | 8.8 | 9.9 | 11 | 13.2 | 16.5 | ||||
| Rated AC output current (A) | 4.6/4.4 | 6.1/5.8 | 7.6/7.3 | 9.1/8.7 | 10.7/10.2 | 12.2/11.6 | 13.7/13.1 | 15.2/14.5 | 18.2/17.4 | 22.8/21.8 | ||||
| Max. AC Output Current(A) | 5/4.8 | 6.7/6.4 | 8.4/8 | 10/9.6 | 11.7/11.2 | 13.4/12.8 | 15/14.4 | 16.7/16 | 20/19.2 | 25/24 | ||||
| Rated output voltage/range (V) | 220/380V, 230/400V 0.85Un-1.1Un | |||||||||||||
| Grid Connection Form | 3L/N/PE | |||||||||||||
| Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |||||||||||||
| Power Factor Adjustment Range | 0.8 leading to 0.8lagging | |||||||||||||
| Total Current Harmonic Distortion THDi | <3% | |||||||||||||
| DC Injection Current | <0.5%ln | |||||||||||||
| Efficiency | ||||||||||||||
| Max. Efficiency | 98.1% | 98.2% | 98.3% | 98.5% | ||||||||||
| Euro Efficiency | 97.5% | 97.6% | 97.8% | 98% | ||||||||||
| MPPT Efficiency | >99% | |||||||||||||
| Equipment Protection | ||||||||||||||
| DC Reverse Polarity Protection | YES | |||||||||||||
| AC Output Overcurrent Protection | YES | |||||||||||||
| AC Output Overvoltage Protection | YES | |||||||||||||
| AC Output Short Circuit Protection | YES | |||||||||||||
| Thermal Protection | YES | |||||||||||||
| Insulation Impedance Detection | YES | |||||||||||||
| DC Component Monitoring | YES | |||||||||||||
| Arc Fault Circuit Interrupter (AFCI) | Optional | |||||||||||||
| Anti-islanding Protection | YES | |||||||||||||
| Residual Current Detection | YES | |||||||||||||
| Surge Protection Level | TYPE II(DC),TYPE II(AC) | |||||||||||||
| DC Switch | YES | |||||||||||||
| Interface | ||||||||||||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) | |||||||||||||
| Communication Interface | RS485/RS232 | |||||||||||||
| General Data | ||||||||||||||
| Operating Temperature Range (°C) | -25 to +60℃, >45℃ Derating | |||||||||||||
| Permissible Ambient Humidity | 0~100% | |||||||||||||
| Permissible Altitude (m) | 4000m | |||||||||||||
| Noise (dB) | <45 | |||||||||||||
| Ingress Protection(IP) Rating | IP 65 | |||||||||||||
| Inverter Topology | Non-Isolated | |||||||||||||
| Over Voltage Category | OVC II(DC),OVC III(AC) | |||||||||||||
| Cabinet Size (WxHxD mm) | 283×525×178 (Excluding Connectors and Brackets) | |||||||||||||
| Weight [kg] | 11.5 | |||||||||||||
| Warranty | 5 Years | |||||||||||||
| Type Of Cooling | natural cooling | |||||||||||||
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98,G99,VDE-AR-N 4105 | |||||||||||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||||||||||