100kW PCS + 200kW MPPT + 500kW STS
BOS-B Battery, 215kWh | 280Ah

Product


| MPPT Module | SUN-MPPT-L01-EU-AM8 | ||||
|---|---|---|---|---|---|
| PV String Input Data | |||||
| Max. PV Input Power (kW) | 200 | ||||
| Max. PV Input Voltage (V) | 800 | ||||
| Start-up Voltage (V) | 200 | ||||
| MPPT Voltage Range (V) | 180-750 | ||||
| Full Load MPPT Voltage Range(V) | 450-750 | ||||
| Rated PV Input Voltage (V) | 600 | ||||
| Max. Operating PV Input Current (A) | 40+40+40+40+40+40+40+40 | ||||
| Max. Input Short-Circuit Current (A) | 60+60+60+60+60+60+60+60 | ||||
| No. of MPP Trackers | 8 | ||||
| Efficiency | |||||
| Max. Efficiency | >99% | ||||
| MPPT Efficiency | >99.9% | ||||
| Equipment Protection | |||||
| DC input reverse protection | YES | ||||
| DC ARC protection | Optional | ||||
| Anti-PID(Potential Induced Degradation) | Optional | ||||
| DC Input Switch | YES | ||||
| Surge Protection Level | TYPE II | ||||
| General Data | |||||
| Ingress Protection(IP) Rating) | IP65 | ||||
| Over Voltage Category | OVC II | ||||
| Cabinet Size[W×H×D] (mm) | 543x198x700 | ||||
| Weight (kg) | 41.75 | ||||
| Type Of Cooling | Intelligent air cooling | ||||
| Safety EMC/Standard | IEC/EN 62109-1 | ||||
| DC Output Current(A) | |||||
| DC Output VoltageRange ( V ) | 630-1000 | ||||
| Max. DCOutput Current ( A ) | 200 | ||||
| STS Module | SUN-STS500L | ||||
|---|---|---|---|---|---|
| Grrid/PCS Side Data | |||||
| Rated AC Input/Output Active Power(kW) | 500 | ||||
| Rated AC Input/Output Current(A) | 758/725 | ||||
| Rated Input/Output Voltage(V) | 220/380, 230/400 (three phase) | ||||
| Grid Connection Form | 3L/N/PE | ||||
| Rated Input/Output Grid Frequency | 50Hz/60Hz | ||||
| GEN Side Data | |||||
| Rated AC Input Active Power(kW)) | 500 | ||||
| Rated AC Input Current(A) | 758/725 | ||||
| Rated Input Voltage(V) | 220/380, 230/400 (three phase) | ||||
| Grid Connection Form | 3L/N/PE | ||||
| Rated Input Grid Frequency | 50Hz/60Hz | ||||
| General Data | |||||
| Off grid switching time | <20ms | ||||
| Ingress Protection(IP) Rating | IP20 | ||||
| Over Voltage category | OVC III | ||||
| Cabinet Size[W×H×D] (mm) | 543x575x671 | ||||
| Weight (kg) | 108 | ||||
| Type Of Cooling | Natural Cooling | ||||
| Safety EMC/Standard | IEC/EN 61439-1/-2 | ||||
| PCS Model | SUN-100K-PCS01HP3 | SUN-125K-PCS01HP3 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Battery Data | ||||||||||
| Battery Type | Lithium-ion | Lithium-ion | ||||||||
| Battery Voltage Range (V) | 630-1000 | 630-1000 | ||||||||
| Max. Charging Current (A) | 175 | 200 | ||||||||
| Max. Discharging Current (A) | 175 | 200 | ||||||||
| Charging Strategy for Li-ion Battery | Self-adaption to BMS | Self-adaption to BMS | ||||||||
| Number of Battery Input | 1 | 1 | ||||||||
| DC Input Data | ||||||||||
| DC Input Voltage Range(V) | 630-1000 | 630-1000 | ||||||||
| Max. DC Input Current(A) | 200 | 200 | ||||||||
| AC Input/Output Data | ||||||||||
| Rated AC Input/Output Active Power (kW) | 100 | 125 | ||||||||
| Max. AC Input/Output Apparent Power (kVA) | 110 | 125 | ||||||||
| Rated AC Input/Output Current (A) | 151.6/145 | 189.4/181.2 | ||||||||
| Max. AC Input/Output Current (A) | 166.7/159.5 | 189.4/181.2 | ||||||||
| Rated Input/Output Voltage/Range(V) | 220/380, 230/400 0.85Un-1.1Un | 220/380, 230/400 0.85Un-1.1Un | ||||||||
| Grid Connection Form | 3L+N+PE | 3L+N+PE | ||||||||
| Rated Input/Output Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz | ||||||||
| Power Factor Adjustment Range | -1~1 | -1~1 | ||||||||
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | <3% (of nominal power) | ||||||||
| DC Injection Current | <0.5% In | <0.5% In | ||||||||
| Efficiency | ||||||||||
| Max. Efficiency | 98.5% | 98.5% | ||||||||
| Euro Efficiency | 97.8% | 97.8% | ||||||||
| MPPT Efficiency | >99% | >99% | ||||||||
| Equipment Protection | ||||||||||
| AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, Anti – islanding Protection, Insulation Impedance Detection,Residual Current Detection | AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, Anti – islanding Protection, Insulation Impedance Detection,Residual Current Detection | |||||||||
| Surge Protection Level | TYPE II(DC),TYPE II(AC) | TYPE II(DC),TYPE II(AC) | ||||||||
| Interface | ||||||||||
| LCD/LED display | LCD | LCD | ||||||||
| Communication Interface | WIFI, RS485, CAN, Meter | WIFI, RS485, CAN, Meter | ||||||||
| General Data | ||||||||||
| Operating Temperature Range(℃) | -40℃to -60℃,>45℃ Derating | -40℃to -60℃,>45℃ Derating | ||||||||
| Permissible Ambient Humidity | 0-95% | 0-95% | ||||||||
| Permissible Altitude | 4000m | 4000m | ||||||||
| Noise | <75dB | <75dB | ||||||||
| Ingress Protection(IP) Rating | IP 65(PCS Module) | IP 65(PCS Module) | ||||||||
| Cabinet Size[W×H×D] (mm) | 543x310x775 | 543x310x775 | ||||||||
| Weight (kg) | 70.35 | 70.35 | ||||||||
| Inverter Topology | Non-Isolated | Non-Isolated | ||||||||
| Over Voltage Category | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | ||||||||
| Type of Cooling | Intelligent Air Cooling | Intelligent Air Cooling | ||||||||
| Warranty | 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | ||||||||
| Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99,VDE-AR-N 4105 | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99,VDE-AR-N 4105 | ||||||||
| Safety/EMC Standard | IEC/EN 62477-1 | IEC/EN 62477-1 | ||||||||
| Model | BOS-B | ||||
|---|---|---|---|---|---|
| Main Parameter | |||||
| Battery Module Energy ( kWh ) | 14.3 | ||||
| Battery Module Nominal Voltage ( V ) | 51.2 | ||||
| Battery Module Capacity ( Ah ) | 280 | ||||
| Module Weight Approximate ( kg ) | 123 | ||||
| Battery Module Qty In Series ( Optional ) | 15 | ||||
| Scalability | 14-15 units for PCS on-grid applications 15 units for PCS off-grid applications 5-15 units for hybrid inverter systems | ||||
| System Nominal Voltage ( V ) | 768 | ||||
| System Energy ( kWh ) | 214.5 | ||||
| System Usable Energy ( kWh ) | 193.05 | ||||
| Charge/Discharge Current ( A ) | Recommend:140 Max:168 | ||||
| Other Parameter | |||||
| Operating Temperature ( ℃ ) | discharge :-20 ~ 55 charge :0 ~ 55 | ||||
| Storage Temperature ( ℃ ) | 0 ~ 35 | ||||
| Thermal Management | Smart fan cooling | ||||
| LCD Display | SOC / Fault Code | ||||
| Status Indicator | Yellow : Battery High Voltage Power On Red : Battery System Alarm | ||||
| Communication Port | TCP / RS485 / CAN | ||||
| Communication With BMS | CAN | ||||
| Humidity | 5% ~ 85% | ||||
| Altitude | ≤3000m | ||||
| IP Rating of Enclosure | IP20 | ||||
| Noise ( dB ) | TBD | ||||
| System Dimension ( W × H × D, mm ) | 2150 × 1136 × 800 | ||||
| System Weight Approximate ( kg ) | 1944 | ||||
| Installation Location | Rack Mounted | ||||
| Rack MountedRecommend Depth of Discharge | 90% | ||||
| Cycle Life | 25±2°C, 0.5C / 0.5C, EOL70%≥6000 | ||||
| Warranty Period | 10 years | ||||
| Certification | CE / IEC62619 / IEC62040 / UN38.3 | ||||
| Model | BOS-B Pro-A3 | ||||
|---|---|---|---|---|---|
| Main Parameter | |||||
| Battery Module Energy ( kWh ) | 16.08 | ||||
| Battery Module Nominal Voltage ( V ) | 51.2 | ||||
| Battery Module Capacity ( Ah ) | 314 | ||||
| Module Weight Approximate ( kg ) | 123 | ||||
| Battery Module Qty In Series ( Optional ) | 15 | ||||
| Scalability | 14-15 units for PCS on-grid applications 15 units for PCS off-grid applications 5-15 units for hybrid inverter systems | ||||
| System Nominal Voltage ( V ) | 768 | ||||
| System Energy ( kWh ) | 241.15 | ||||
| System Usable Energy ( kWh ) | 217.04 | ||||
| Max.Charge/Discharge Current ( A) | 180 | ||||
| Other Parameter | |||||
| Operating Temperature ( ℃ ) | Charge :0 ~ 55 Discharge :-20 ~ 55 | ||||
| Storage Temperature ( ℃ ) | 0 ~ 35 | ||||
| Thermal Management | Smart fan cooling | ||||
| LCD Display | SOC / Fault Code | ||||
| Status Indicator | Yellow : Battery High Voltage Power On Red : Battery System Alarm | ||||
| Communication Port | CP / RS485 / CAN | ||||
| Communication With BMS | CAN | ||||
| Humidity | 5% ~ 85% | ||||
| Altitude | ≤3000m | ||||
| IP Rating of Enclosure | IP20 | ||||
| Noise ( dB ) | TBD | ||||
| System Dimension ( W × H × D, mm ) | 2150 × 1136 × 800 | ||||
| System Weight Approximate ( kg ) | 1850 | ||||
| Installation Location | Rack Mounted | ||||
| Recommend Depth of Discharge | 90% | ||||
| Cycle Life | 25±2°C, 0.5C / 0.5C, EOL70%≥6000 | ||||
| Warranty Period | 10 years | ||||
| Certification | CE / IEC62619 / IEC62040 / UN38.3 | ||||