Skip to main content

Solar Pay Nigeria Limited

SUN-3/3.6/5/6K-SG04LP1-EU-SM1/SM2

Single Phase Hybrid Inverter |  3-6kW | 2 MPPT | LV Battery Supported

No content is added yet.

Specifications

  •  Colorful touch LCD, IP65 protection degree
  • AC couple to retrofit existing solar system
  • Max. 16 pcs parallel for on-grid and off-grid
    operation; Support multiple batteries parallel
  • Max. charging/discharging current of 140A
  • 6 time periods for battery charging/discharging
  • Support storing energy from diesel generator

Technical specifications

Model SUN-3K-SG04LP1-24-EU-SM1 SUN-3K-SG04LP1-EU-SM1 SUN-3.6K-SG04LP1-EU-SM2 SUN-5K-SG04LP1-EU-SM2 SUN-6K-SG04LP1-EU-SM2 .
Battery Input Data. –.
Battery TypeLead-acid or Lithium-ion
Battery Voltage Range(V)20-3040-60
Max.Charging Current(A)1407090120135
Max.Discharging Current(A)1407090120135
Charging Strategy for Li-ion BatterySelf-adaption to BMS
Number of battery input1
PV String Input Data
Max. PV Access Power (W)6000600072001000012000
Max PV Input Power(W)48004800576080009600
Max PV Input Voltage(V)500
Start-up Voltage(V)125
MPPT Voltage Range(V)150-425
Rated PV Input Voltage(V)370
Max Input Short-Circuit Current(A)2727+27
Max Operating PV Input Current(A)1818+18
No.of MPP Trackers/No.of String Per MPP Tracker1/12/1+1
AC Input /Output Data
Rated AC Input/Output Active Power(W)3000360050006000
Max AC Input/Output Apparent Power (VA)3300396055006600
Rated AC Input/Output Current(A)13.7/13.116.4/15.722.8/21.827.3/26.1
Max AC Input/Output Current(A)15/14.418/17.3*25/2430/28.7
Max Continuous AC Passthrough (grid to load)(A)3540
Peak Power (off-grid)(W)2 times of rated power,10s
Rated Input/Output Voltage/Range(V)220V/230 0.85Un-1.1Un
Grid Connection FormL+N+PE
Rated Input/Output Grid Frequency/Range50Hz/45Hz-55Hz 60Hz/55Hz-65Hz
Power Factor Adjustment Range0.8 leading to 0.8lagging
Total Current Harmonic Distortion THDi<3% (of nominal power)
DC Injection Current<0.5%ln
Efficiency
Max Efficiency97.6%
Euro Efficiency96.5%
MPPT Efficiency>99%
Equipment Protection
IntegratedDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface
Communication InterfaceRS485/RS232/CAN
Monitor ModeGPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data.....
Operating Temperature Range-40 to+60℃,>45℃ Derating....
Permissible Ambient Humidity0~100%....
Permissible Altitude2000m....
Noise<30....
Ingress Protection(IP) RatingIP 65....
Inverter TopologyNon-Isolated....
Over Voltage CategoryOVC II(DC),OVC III(AC)....
Cabinet size(W*H*D)[mm]376*470*241.5(Excluding connectors and brackets)....
Weight[kg]17.619..
Warranty5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy....
Type Of Coolingnatural cooling....
Grid RegulationIEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105....
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2...

*For the SUN-3.6K-SG04LP1-EU-SM2, the maximum output current will be capped at 15.7A to comply with the G98 standard.