Product
Three Phase | 18-25kW | 2 MPPT


| Model | SUN-18K-G05 | SUN-20K-G05 | SUN-22K-G05 | SUN-23K-G05 | SUN-25K-G05 | ||||
|---|---|---|---|---|---|---|---|---|---|
| PV String Input Date | |||||||||
| Max. PV Input Power(kW) | 23.4 | 26 | 28.6 | 29.9 | 32.5 | ||||
| Max. PV Input Voltage(V) | 1100 | ||||||||
| Start-up Voltage(V) | 250 | ||||||||
| MPPT voltage range(V) | 200-1000 | ||||||||
| Rated PV Input voltage(V) | 600 | ||||||||
| Max. Operating PV Input Current (A) | 26+26 | ||||||||
| Max. Input Short Circuit Current (A) | 39+39 | ||||||||
| No. of MPP Trackers/No. of Strings MPP Tracker | 2/2+2 | ||||||||
| AC Output Side | |||||||||
| Rated AC Output Active Power (kW) | 18 | 20 | 22 | 23 | 25 | ||||
| Max. AC Output Apparent Power (kVA) | 19.8 | 22 | 24.2 | 25.3 | 2.75 | ||||
| Rated AC output current (A) | 27.3/26.1 | 30.3/29 | 33.4/31.9 | 34.9/33.4 | 37.9/36.2 | ||||
| Max. AC Output Current(A) | 30/28.7 | 33.3/31.9 | 36.7/35.1 | 38.4/36.7 | 41.7/39.8 | ||||
| Rated output voltage/range (V) | 220/380V, 230/400V 0.85Un-1.1Un | ||||||||
| Grid Connection Form | 3L/N/PE | ||||||||
| Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | ||||||||
| Power Factor Adjustment Range | 0.8 leading to 0.8lagging | ||||||||
| Total Current Harmonic Distortion THDi | <3% | ||||||||
| DC Injection Current | <0.5%ln | ||||||||
| Efficiency | |||||||||
| Max. Efficiency | 98.50% | ||||||||
| Euro Efficiency | 98% | ||||||||
| MPPT Efficiency | >99% | ||||||||
| Equipment Protection | |||||||||
| DC Reverse Polarity Protection | YES | ||||||||
| AC Output Overcurrent Protection | YES | ||||||||
| AC Output Overvoltage Protection | YES | ||||||||
| AC Output Short Circuit Protection | YES | ||||||||
| Thermal Protection | YES | ||||||||
| Insulation Impedance Detection | YES | ||||||||
| DC Component Monitoring | YES | ||||||||
| Arc Fault Circuit Interrupter (AFCI) | Optional | ||||||||
| Anti-islanding Protection | YES | ||||||||
| Residual Current Detection | YES | ||||||||
| Surge Protection Level | TYPE II(DC),TYPE II(AC) | ||||||||
| DC Switch | YES | ||||||||
| Interface | |||||||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) | ||||||||
| Communication Interface | RS485/RS232 | ||||||||
| General Data | |||||||||
| Operating Temperature Range (°C) | -25 to +60℃, >45℃ Derating | ||||||||
| Permissible Ambient Humidity | 0~100% | ||||||||
| Permissible Altitude (m) | 4000m | ||||||||
| Noise (dB) | ≤ 50dB(A) | ||||||||
| Ingress Protection(IP) Rating | IP 65 | ||||||||
| Inverter Topology | Non-Isolated | ||||||||
| Over Voltage Category | OVC II(DC),OVC III(AC) | ||||||||
| Cabinet Size (WxHxD mm) | 362mm*527mm*220mm(Excluding connectors and brackets) | ||||||||
| Weight [kg] | 20 | ||||||||
| Warranty | 5 Years | ||||||||
| Type Of Cooling | Intelligent air cooling | ||||||||
| Grid Regulation | IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 | ||||||||