Skip to main content

Solar Pay Nigeria Limited

SUN-3/4/5/6/8/10/12K-SG05LP3-EU-SM2

Single Phase Hybrid Inverter |  3-6kW | 2 MPPT | LV Battery Supported

No content is added yet.

Specifications

    • 100% unbalanced output
    • AC couple to retrofifit existing solar system
    • Max. 10 pcs parallel for on-grid and off-grid
      operation; Support multiple batteries parallel
    • Max. charging/discharging current of 240A
    • Support storing energy from diesel generator
    • 48V low voltage battery, transformer isolation design
    • 6 time periods for battery charging/discharging

Technical specifications

Modelo SUN-3K-SG05 LP3-EU-SM2 SUN-4K-SG05 LP3-EU-SM2 SUN-5K-SG05 LP3-EU-SM2 SUN-6K-SG05 LP3-EU-SM2 SUN-8K-SG05 LP3-EU-SM2 SUN-10K-SG05 LP3-EU-SM2 SUN-12K-SG05 LP3-EU-SM2
Battery Input Data–––––––
Battery TypeLead-acid or Lithium-ion––––––
Battery Voltage Range(V)40-60––––––
Max.Charging Current(A)7095120135190210240
Max.Discharging Current(A)7095120135190210240
Charging Strategy for Li-ion BatterySelf-adaption to BMS––––––
Number of battery input1––––––
PV String Input Data–––––––
Max. PV Access Power (W)600080001000012000160002000024000
Max PV Input Power(W)4500640080009600128001600019200
Max PV Input Voltage(V)800––––––
Start-up Voltage(V)160––––––
MPPT Voltage Range(V)200-650––––––
Rated PV Input Voltage(V)550––––––
Max Input Short-Circuit Current(A)30+3039+39–––––
Max Operating PV Input Current(A)20+2026+26–––––
No.of MPP Trackers/No.of String Per MPP Tracker2/1+12/2+2–––––
AC Input /Output Data–––––––
Rated AC Input/Output Active Power(W)300040005000600080001000012000
Max AC Input/Output Apparent Power (VA)330044005500660088001100013200
Rated AC Input/Output Current(A)4.6/4.46.1/5.87.6/7.39.1/8.712.2/11.615.2/14.518.2/17.4
Max AC Input/Output Current(A)5/4.86.7/6.48.4/810/9.613.4/12.816.7/1620/19.2
Max Continuous AC Passthrough (grid to load)(A)45––––––
Peak Power (off-grid)(W)2 times of rated power,10s––––––
Power Factor Adjustment Range0.8 leading to 0.8 lagging––––––
Rated Input/Output Voltage/Range(V)220/380V, 230/400V 0.85Un-1.1Un––––––
Grid Connection Form3L+N+PE––––––
Rated Input/Output Grid Frequency/Range50/45-55, 60/55-65––––––
Total Current Harmonic Distortion THDi<3% (of nominal power)––––––
DC Injection Current<0.5% In––––––
Efficiency–––––––
Max Efficiency97.6%––––––
Euro Efficiency97.0%––––––
MPPT Efficiency>99%––––––
Equipment Protection–––––––
IntegratedDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection––––––
Surge Protection LevelTYPE II(DC),TYPE II(AC)––––––
Interface–––––––
Communication InterfaceRS485/RS232/CAN––––––
Monitor ModeGPRS/WIFI/Bluetooth/4G/LAN(optional)––––––
General Data–––––––
Operating Temperature Range-40 to+60℃,>45℃ Derating––––––
Permissible Ambient Humidity0~100%––––––
Permissible Altitude3000m––––––
Noise (dB)≤55––––––
Ingress Protection(IP) RatingIP 65––––––
Inverter TopologyNon-Isolated––––––
Over Voltage CategoryOVC II(DC),OVC III(AC)––––––
Cabinet Size (WxHxD mm)386×660×250 (Excluding Connectors and Brackets)––––––
Weight[kg]35.2––––––
Warranty5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy––––––
Type Of CoolingIntelligent Air Cooling––––––
Grid RegulationIEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25,G98, G99,VDE-AR-N 4105––––––
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2––––––