Specifications

  • 100% unbalanced output
  • AC couple to retrofit existing solar system
  • Max. 10 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
  • Max. charging/discharging current of 50A
  • High voltage battery, higher efficiency
  • 6 time periods for battery charging/discharging
  • Support storing energy from diesel generator

Technical specifications

Model SUN-8K-SG01HP2 -US-AM2 SUN-10K-SG01HP2 -US-AM2 SUN-12K-SG01HP2 -US-AM2 SUN-15K-SG01HP2 -US-AM2
Battery Input Data
Battery TypeLead-acid or Lithium-ion
Battery Voltage Range(V)160-500
Max.Charging Current(A)50
Max.Discharging Current(A)50
Charging Strategy for Li-ion BatterySelf-adaption to BMS
Number of battery input1
PV String Input Data
Max. PV Access Power (W)16000200002400030000
Max PV Input Power(W)12000150001800022500
Max PV Input Voltage(V)5500
Start-up Voltage(V)180
MPPT Voltage Range(V)150-500
Rated PV Input Voltage(V)380
Max Input Short-Circuit Current(A)26+26
Max Operating PV Input Current(A)39+39
No.of MPP Trackers/No.of String Per MPP Tracker2/2+2
AC Input /Output Data
Rated AC Input/Output Active Power(W)8000100001200015000
Max AC Input/Output Apparent Power (VA)8000100001200015000
Rated AC Input/Output Current(A)33.441.75062.5
Max AC Input/Output Current(A)33.441.75062.5
Max Continuous AC Passthrough (grid to load)(A)150
Peak Power (off-grid)(W)1.5 times of rated power, 10s
Rated Input/Output Voltage/Range(V)120/240, 208 0.85Un-1.1Un
Grid Connection Form2L+N+PE
Rated Input/Output Grid Frequency/Range60/55-65
Power Factor Adjustment Range0.8 leading to 0.8lagging
Total Current Harmonic Distortion THDi<3% (of nominal power)
DC Injection Current<0.5%ln
Efficiency
Max Efficiency97.6%
Euro Efficiency97.0%
MPPT Efficiency>99%
Equipment Protection
IntegratedDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface
Communication InterfaceRS485/RS232/CAN
Monitor ModeGPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range-40 to+60℃,>45℃ Derating
Permissible Ambient Humidity0~100%
Permissible Altitude2000m
Noise≤55
Ingress Protection(IP) RatingTYPE3R
Inverter TopologyNon-Isolated
Over Voltage CategoryOVC II(DC),OVC III(AC)
Cabinet size(W*H*D)[mm]436×680×277.5 (Excluding Connectors and Brackets)
Weight[kg]34.8
Warranty5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Type Of CoolingIntelligent Air Cooling
Grid RegulationIEEE 1547.1,SRD V2.0
Safety EMC/StandardFCC, UL 1741

*For the SUN-3.6K-SG04LP1-EU-SM2, the maximum output current will be capped at 15.7A to comply with the G98 standard.