Three Phase Hybrid Inverter | 8-15kW | 2 MPPT | HV Battery Supported


| Model | SUN-8K-SG01HP2 -US-AM2 | SUN-10K-SG01HP2 -US-AM2 | SUN-12K-SG01HP2 -US-AM2 | SUN-15K-SG01HP2 -US-AM2 | ||||
|---|---|---|---|---|---|---|---|---|
| Battery Input Data | ||||||||
| Battery Type | Lead-acid or Lithium-ion | |||||||
| Battery Voltage Range(V) | 160-500 | |||||||
| Max.Charging Current(A) | 50 | |||||||
| Max.Discharging Current(A) | 50 | |||||||
| Charging Strategy for Li-ion Battery | Self-adaption to BMS | |||||||
| Number of battery input | 1 | |||||||
| PV String Input Data | ||||||||
| Max. PV Access Power (W) | 16000 | 20000 | 24000 | 30000 | ||||
| Max PV Input Power(W) | 12000 | 15000 | 18000 | 22500 | ||||
| Max PV Input Voltage(V) | 5500 | |||||||
| Start-up Voltage(V) | 180 | |||||||
| MPPT Voltage Range(V) | 150-500 | |||||||
| Rated PV Input Voltage(V) | 380 | |||||||
| Max Input Short-Circuit Current(A) | 26+26 | |||||||
| Max Operating PV Input Current(A) | 39+39 | |||||||
| No.of MPP Trackers/No.of String Per MPP Tracker | 2/2+2 | |||||||
| AC Input /Output Data | ||||||||
| Rated AC Input/Output Active Power(W) | 8000 | 10000 | 12000 | 15000 | ||||
| Max AC Input/Output Apparent Power (VA) | 8000 | 10000 | 12000 | 15000 | ||||
| Rated AC Input/Output Current(A) | 33.4 | 41.7 | 50 | 62.5 | ||||
| Max AC Input/Output Current(A) | 33.4 | 41.7 | 50 | 62.5 | ||||
| Max Continuous AC Passthrough (grid to load)(A) | 150 | |||||||
| Peak Power (off-grid)(W) | 1.5 times of rated power, 10s | |||||||
| Rated Input/Output Voltage/Range(V) | 120/240, 208 0.85Un-1.1Un | |||||||
| Grid Connection Form | 2L+N+PE | |||||||
| Rated Input/Output Grid Frequency/Range | 60/55-65 | |||||||
| Power Factor Adjustment Range | 0.8 leading to 0.8lagging | |||||||
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | |||||||
| DC Injection Current | <0.5%ln | |||||||
| Efficiency | ||||||||
| Max Efficiency | 97.6% | |||||||
| Euro Efficiency | 97.0% | |||||||
| MPPT Efficiency | >99% | |||||||
| Equipment Protection | ||||||||
| Integrated | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | |||||||
| Surge Protection Level | TYPE II(DC),TYPE II(AC) | |||||||
| Interface | ||||||||
| Communication Interface | RS485/RS232/CAN | |||||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) | |||||||
| General Data | ||||||||
| Operating Temperature Range | -40 to+60℃,>45℃ Derating | |||||||
| Permissible Ambient Humidity | 0~100% | |||||||
| Permissible Altitude | 2000m | |||||||
| Noise | ≤55 | |||||||
| Ingress Protection(IP) Rating | TYPE3R | |||||||
| Inverter Topology | Non-Isolated | |||||||
| Over Voltage Category | OVC II(DC),OVC III(AC) | |||||||
| Cabinet size(W*H*D)[mm] | 436×680×277.5 (Excluding Connectors and Brackets) | |||||||
| Weight[kg] | 34.8 | |||||||
| Warranty | 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | |||||||
| Type Of Cooling | Intelligent Air Cooling | |||||||
| Grid Regulation | IEEE 1547.1,SRD V2.0 | |||||||
| Safety EMC/Standard | FCC, UL 1741 | |||||||
*For the SUN-3.6K-SG04LP1-EU-SM2, the maximum output current will be capped at 15.7A to comply with the G98 standard.